MECH Dept Engineering Topics List

Circuit and Construction, Operation

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Fig.14.11 shows how two pressure switches can be used to control the operation of a double-acting hydraulic cylinder.

control of a hydraulic cylinder using a single limit switch

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

An electrohydraulic system which uses a single solenoid valve and a single limit switch to control a double-acting hydraulic cylinder is illustrated in Fig. 14.10.

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

It should be noted that while drawing any electrohydraulic (or electropneumatic) circuits, separate circuits should be drawn for the fluid system and the electrical system.

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

The most commonly used electrical control devices are :

Learning Objectives, Introduction

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Nowadays, the focus has been shifted from manual control to electrical control of fluid power systems.

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Review questions: Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Review and summary: Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Multi-cylinder pneumatic circuits can be designed in various methods.

multi-actuator circuits

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

In the preceding sections, we have discussed various single-actuator circuits.

Circuit, Operation

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

As discussed in Section 12.6, pneumatic time delay valve is used in time based sequencing circuits to achieve the intended time delays between specific operations.

Circuit, Operation

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

Fig.13.12 illustrates a circuit to control unidirectional pneumatic motor.

Pneumatic and Electro Pneumatic Systems - Hydraulics and Pneumatics

Subject and UNIT: Hydraulics and Pneumatics: Unit IV: Pneumatic and Electro Pneumatic Systems

In many pneumatic applications, it is required to operate different components with different speeds.